1.5 Standards
This product complies with the requirements of the following standards.
In addition, boards ordered with the ruggedized service comply with the following standards as well.
Note:
Customers desiring to perform further environmental testing of the CP6005(X)-SA must
contact Kontron for assistance prior to performing any such testing.
Boards
without conformal coating must not be exposed to a change of temperature which
can lead to condensation. Condensation may cause irreversible damage, especially when
the board is powered up again.
Kontron does not accept any responsibility for damage to products resulting from destruc-
tive environmental testing.
Table 2: Standards
TYPE
ASPECT
STANDARD
CE
Emission
EN55022, EN61000-6-3
Immission
EN55024, EN61000-6-2
Electrical Safety
EN60950-1
Mechanical
Mechanical Dimensions
IEEE 1101.10
Environmental
Climatic Humidity
IEC60068-2-78 (see note below)
WEEE
Directive 2002/96/EC
Waste electrical and electronic equipment
RoHS 2
Directive 2011/65/EU
Restriction of the use of certain hazardous sub-
stances in electrical and electronic equipment
Table 3: Additional Standards for Boards Ordered with Ruggedized Service
TYPE
ASPECT
STANDARD
REMARKS
Environmental
Vibration
(Sinusoidal)
IEC60068-2-6
Ruggedized version test parameters:
10-300 (Hz) frequency range
2 (g) acceleration
1 (oct/min) sweep rate
10 cycles/axis
3 axes
Single Shock
IEC60068-2-27
Ruggedized version test parameters:
30 (g) acceleration
9 (ms) shock duration half sine
3 number of shocks per direction (total: 18)
6 directions
5 (s) recovery time
Permanent Shock
IEC60068-2-29
Ruggedized version test parameters:
15 (g) acceleration
11 (ms) shock duration half sine
500 number of shocks per direction
6 directions
5 (s) recovery time