Operation

| 29

Command

Format

Example

Description

Set CC Limit

LLxxx.x

(x = 000.0–999.9)

LL000.0

Sets CC limit in non-

continuous mode.

Query CC Limit

LL?

Returns CC limit

Query Motion

Direction

DIR?

Reports

motion

direction: CW, CC or N

(no motion)

Seek

SKxxx.x

(x=000.0—999.9)

SK180.0

Seeks specified target

in degrees

A carriage return (0x0D) must be sent at the end of every command.

An acknowledge byte (0x06) is returned after all non-query

commands.

Ensure the current travel limit settings will not

cause damage to existing cables.

Do not operate the AP in a stalled condition.

Doing so can cause damage to the drive unit

and will void the warranty. Ensure the

positioner will continue to rotate under load at

all speeds.