LMF 3995-RS232 RFI/EMI Filter
Marking and Documentation
The filter contains an identification label that states manufacturer’s name, model
of filter and serial number. The label also establishes the frequencies of
operation, voltage, current rating and impedance (if applicable). The filter
contains necessary labels indicating which terminals are grounded, danger of
high voltage and the need for discharging of capacitors.
Filter Testing
The ability to provide the customer with a highly reliable product demands
repeatability and controlled processing. We have achieved this objective using
testing procedures to verity that filter products conform to original design
parameters. Testing is performed in accordance with Military Specifications that
include MIL-F-15733, MIL-STD-220A, as well as commercial specification UL-
1283. Precision electronic test instruments are utilized to accurately measure the
characteristics of each filter. Test reports are available upon request.
Protection Against Electric Shock
Protective earthing is accomplished by means of a screwed on cover that is in
contact with the body of the filter. This cover protects against accidental contact
with live terminals and also provides a ground path by means of the body of the
filter. The filter, when in use, should be permanently grounded by means of
grounding connection and also by contact of the filter to the grounded surface to
which it is attached. This arrangement provides for very low impedance from the
filter body to earth ground.