Series 5900 Inside Glazed Curtain Wall Installation Instructions

Section IX: Glazing

Glazing

A.)

Clean all glazing pockets prior to glazing. This is necessary to avoid clogging the

weep system and staining the exterior metal and glass surfaces.

B.)

Apply the preset glazing gaskets to the horizontal exterior glazing pockets.

FIG. 3



1.) Apply silicone sealant into the raceway a minimum of 2” each way at all corners

to the inside face of the glazing pocket. See FIG. 3

2.) Gaskets can become somewhat deformed during storage in cartons. The

gaskets should be removed from the cartons and / or rolls several hours prior

to use and laid flat or hung to allow for recovery of the correct shapes. The

temperature must be at least 50 degrees to allow this recovery.

3.) Cut vertical gaskets D.L.O. + 1 ¾”

4.) Cut horizontal gaskets D.L.O. + ½”

Note: If the exterior gaskets are

difficult to install into the
glazing race, a light coat of
mineral spirits may be

applied to the gasket.

Sealant

(Ref. to Section B.1 & 5 below)

Preset gasket

Exterior dense preset

Interior dense wedge gasket