Warning, Led lighthead flash pattern – Code 3 WingMan for Crown Victoria User Manual
Page 8
8
Larger wires and tight connections will provide longer service life for components. For high current wires it is
highly recommended that terminal blocks or soldered connections be used with shrink tubing to protect the
connections. Do not use insulation displacement connectors (e.g. 3M
®
Scotchlock type connectors). Route
wiring using grommets and sealant when passing through compartment walls. Minimize the number of
splices to reduce voltage drop. High ambient temperatures (e.g. underhood) will significantly reduce the
current carrying capacity of wires, fuses, and circuit breakers. Use "SXL" type wire in engine compartment.
All wiring should conform to the minimum wire size and other recommendations of the manufacturer and be
protected from moving parts and hot surfaces. Looms, grommets, cable ties, and similar installation
hardware should be used to anchor and protect all wiring. Fuses or circuit breakers should be located as
close to the power takeoff points as possible and properly sized to protect the wiring and devices. Particular
attention should be paid to the location and method of making electrical connections and splices to protect
these points from corrosion and loss of conductivity. Ground terminations should only be made to substan-
tial chassis components, preferably directly to the vehicle battery. The user should install a fuse sized to
approximately 125% of the maximum Amp capacity in the supply line to protect against short circuits. For
example, a 30 Amp fuse should carry a maximum of 24 Amps. DO NOT USE 1/4" DIAMETER GLASS
FUSES AS THEY ARE NOT SUITABLE FOR CONTINUOUS DUTY IN SIZES ABOVE 15 AMPS.
Circuit breakers are very sensitive to high temperatures and will "false trip" when mounted in hot environ-
ments or operated close to their capacity.
WARNING!
!
Operating Specifications for directional module:
Operating Voltage: 10-16 VDC, Reverse Polarity Protection
Current Draw : Flashing Module
Red/Amber - .25A avg @ 12.8 Volts
Blue/White - .4A avg @ 12.8 Volts
Steady Burn Module
Red/Amber - .5A avg @ 12.8 Volts
Blue/White - .8A avg @ 12.8 Volts
Available Colors - Red , Blue, Amber, and White
LED MODULES
LED LightHead Flash Pattern
Place the unit on a clean work surface and remove the outer cover. With the chassis facing up, locate each lighthead
module circuit board.
To change the flash patterns of the LED LightHeads, touch both posts of the J1 header
simultaneously with an electrically conductive tool such as a screwdriver blade (see Figure 20). Repeating
this proceedure allows the operator to cycle through the numerous flash patterns offered until the desired
pattern is achieved.
Directional Module Flash Pattern - Table 1
Flash Pattern
Description
Cycle Flash
Cycles through various patterns @ 70 fpm
Steady-Burn
Steady-Burn
Five Flash
Five Pulses per flash @ 70 fpm
Quad Flash
Four Pulses per flash @ 70 fpm
Triple Flash
Three Pulses per flash @ 70 fpm
Double Flash
Two Pulses per flash @ 70 fpm
Fast Double Flash
Two Pulses per flash @ 85 fpm
NFPA
Four Pulses, 70% Duty Cycle @ 75 fpm
Quad Pop Flash
Four Pulses per flash ( 3 equal, 1 extended) @ 70 fpm
Triple Pop Flash
Three Pulses per flash ( 2 equal, 1 extended) @ 70 fpm
Double Pop Flash
Two Pulses per flash ( 1 equal, 1 extended) @ 70 fpm