Installation and Mounting

MOUNTING THE MODEL PSE475 STROBE LIGHT POWER SUPPLY

To obtain maximum performance and durability the Model PSE475 strobe light power supply
should be mounted as follows:

1. Mount the unit with the strobe light outlets located in such a way that they are easily accessible.

2. Mount the unit with the four supplied #8 sheet metal screws. If possible, a metal surface should be
chosen for best heat dissipation. The mounting hole pattern dimensions are shown in Figure 1. The power supply
can be used as a template to mark the drill locations. Predrill this surface with a 9/64 drill and secure
the unit.

WARNING!

!

WIRING

STROBE LIGHT HEAD CABLE CONNECTIONS

1. Install the strobe light heads in the preferred locations and route the shielded three wire cable from the
light heads to the PSE475 power supply. Leave enough cable at the power supply location so that the cables
will not be strained when connected to the power supply outlets. Follow the lighthead user instructions for
connecting the cables to the strobe light heads.

WARNING!

!

The Model PSE475 Strobe Power Supply is NOT waterproof and should be located in an area
protected from the weather and water.

FIGURE 1

4

High voltages and/or temperatures are present inside the unit. Disconnect from power and
wait 10 minutes prior to servicing or troubleshooting. Use hand and eye protection when
changing halogen lamps or flashtubes.