BoonDocker POLARIS: Non-turbo Control Box 2011-12 PRO RMK 800 User Manual
Page 11
![background image](/manuals/635172/11/background.png)
BoonDocker Performance – 2379 Heyrend Way, Idaho Falls, ID 83402 – 208-542-4411 / 877-522-7805
www.boondockers.com – email:
– fax: 208-524-7381
Revised 1-20-11
Copyright © 2011 Boondocker
Page 11 of 17
ARM:
Description: Btn
On for N2O :
ARM
By using a pushbutton (momentary), toggle, rocker, or slide switch connected to the button input, the
nitrous system can be armed or disarmed. When the switch is closed the system is armed and ready.
Then, depending upon other configuration settings, either the TPS or RPM with TPS can activate the
nitrous system. When the switch is open, the system is disarmed so neither TPS nor RPM will result
in nitrous activation.
Nitrous activation idea: One way to use the button for nitrous activation and to have the RPM
limiting feature (to prevent hitting the rev-limiter), set Btn to ARM, TPS to ON (with a low
threshold), and RPM to ON (with desired Min/Max settings).
Press the Left or Right Arrow to return to the N2O menu or push the “SEL” button to return to the Main
Menu.
C. N2O Configuration Examples
The following are examples of settings to achieve the various nitrous triggering configurations described in Section A
above:
1. Button only: Activate nitrous only
when the button is pressed.
Fuel TPS RPM Btn
040 OFF OFF
N2O
Set: TPS to OFF, RPM to OFF, and Btn to
N2O.
2. TPS only: Activate nitrous only
when the throttle is pressed beyond
a set level.
Fuel TPS RPM Btn
040
200 OFF OFF
Set: TPS to ON (set the TPS threshold to the
desired level), RPM to OFF, Btn to OFF.
3. TPS and RPM only: Activate
nitrous only when the throttle is
pressed beyond a set level AND
when RPMs are with a certain
range.
Fuel TPS RPM Btn
040 200
ON OFF
Set: TPS to ON (set TPS threshold to desired
level), RPM to ON (set Min/Max to
desired levels), Btn to OFF.
4. Button (N2O) or TPS: Activate
nitrous when button is pressed OR
when throttle is pressed beyond a
set level.
Fuel TPS RPM Btn
040 200 OFF
N2O
Set: TPS to ON (set TPS threshold to desired
level), RPM to OFF, and Btn to N2O.
5. Button (N2O) or TPS and RPM:
Activate nitrous when button is
pressed OR when throttle is press-
ed beyond a set level AND the
RPMs are within a certain range.
Fuel TPS RPM Btn
040 200 ON
N2O
Set: TPS to ON (set TPS threshold to desired
level), RPM to ON (set Min/Max values),
and Btn to N2O.
6. Button (ARM) and TPS:
Activate nitrous when button input
is on (armed) AND throttle is
pressed beyond a set level.
Fuel TPS RPM Btn
040 200 OFF
ARM
Set: TPS to ON (set TPS threshold to desired
level), RPM to OFF, and Btn to ARM.
7. Button (ARM) and TPS and
RPM: Activate nitrous when
button input is on (armed) AND
throttle is pressed beyond a set
level AND the RPMs are within a
certain range.
Fuel TPS RPM Btn
040 200 ON
ARM
Set: TPS to ON (set TPS threshold to desired
level), RPM to ON (set Min/Max values),
and Btn to ARM.