V. control box menus, Startup screen, Main menu – BoonDocker ARCTIC CAT: Non-turbo Control Box 700/800/1000 (V3) User Manual
Page 4

BoonDocker – 1585 Hollipark Dr. Idaho Falls, ID 83401 – 208-542-4411 / 877-522-7805
www.boondockers.com – email:
– fax: 208-524-7381
Revised 12-14-07
Page 4 of 19
1. Battery Connector
The Control Box is designed to operate without a battery – the box will turn itself on whenever power is applied for the
fuel injectors. However, a 9-volt battery (not included) can be plugged into the box through the Control Box’s connectors
with the supplied battery / jumper connector in order to operate the box without the sled running. This battery connector
plugs into the Control Box’s nitrous connector (refer to picture
below). Secure the battery to the connector with a zip tie in
order to provide a strain relief for the 9-volt connector. The
battery can also be secured to part of the harness if it is to be
used on the sled while it is running.
The battery connector can be left plugged in during engine
operation, but the nitrous harness (if used) cannot be plugged
into the Control Box. The battery will eventually drain if left
connected to the box, so it is best to disconnect the battery
when not in use.
2. Jumper Connector
The Battery/Jumper connector can also be used to bypass the
Control Box in case the sled needs to be run without the
Control Box. Disconnect the Control Box from the EFI harness
and plug in the Jumper connector - the injectors are now
connected directly to the sled’s ECU.
V. Control Box Menus
1. Startup Screen
Every time the box is first turned on (by the engine or battery), the Startup Screen is displayed. Press any key to go to the
Main Menu. An example Startup Screen is shown below:
Arctic Cat 6-900
xxxxxxxx N2O:ADJ
In the example shown above, this screen displays the following information:
Arctic Cat
Sled make
6-900
Sled model
Note: Be sure the Control Box is for your make and model of sled!
xxxxxxxx
Code Version This is the version of code in the box. The version of code can only be changed
by sending the box back to Boondocker.
N2O:
Shows that this Control Box is nitrous capable.
ADJ
Nitrous pressure regulator mode. This mode can be changed in the “Setup Menu”.
2. Main Menu
The Main Menu is shown below:
Main
Fuel Stats
Menu N2O
Map1U
The current selection is shown by the Right-Arrow and the cursor (underscore below the “F”). Use the arrow keys to
move the cursor. Move the cursor to the desired selection and press the “SEL” key to select the desired menu option from
one of the following:
Fuel
Go to the Fuel adjust menus.
Stats
Display runtime data, captured data, and recorded maximum data.