Model 7821 Bench Scale User’s Manual

5

1. Remove contents of the shipping container.

2. Inspect the scale for shipping damage.

Immediately report any damage to the
shipper.

1. Mount the scale on a stable, level surface

that is free from air currents and vibration. Be
sure the scale platter does not touch any
adjacent surfaces.

2. To install the scale surface flush with a

countertop, use these dimensions to guide
your construction:

7821 Platform

Minimum Cutout

Dimensions

Dimensions

14" (35.6cm) W x

14.75" (37.5cm) W x

12.5" (31.7cm) L

13.25" (33.7cm) L

4.1" (10.4cm) Min Ht.

adjustable to 4.6" (11.7cm)

For the optional remote display, attach Velcro™
fasteners to both the back of the display and to
the surface where the display is to be mounted.
To attach the Velcro fasteners, clean the mount-
ing areas thoroughly and press the Velcro into
place. The adhesive adheres best to a smooth,
clean surface.

Velcro is a registered trademark of Velcro USA, Inc.

When the scale is first powered up, it will perform
a test sequence. During this sequence, the
display will show the following:

• The model number and software revision

level

• A numeric counting test for all segments of

the display

Unpacking and Installing the Scale

Operation

Unpacking the Scale

Installing the Scale

Cutout Dimensions

Attaching Velcro™

Fasteners (Optional

remote display only)

Power Up

Test Sequence