Model 7821 Bench Scale User’s Manual
14
The Configuration (CONF) Mode menu allows
configuration of the scale to the specific applica-
tion need. The items you can configure are as
follows:
Filtering (FILT) – Choose between FAST
and SLO filtering. Slow should be chosen in
areas susceptible to vibration. Choose FAST
filtering for more stable conditions.
Baud (BAUD) – Choose a baud and parity
from table.
Protocol (PROT) – Choose serial communi-
cation protocol:
NCI - Ref. 8408-14788-01 (W, S, Z, H, U, M
Only)
8213 - Ref. 8408-14788-03
3835 - Ref. 8408-14788-12
Follow these steps to access and configure the
items in the CONF menu. Refer to Figure 2.
1. From the normal weighing mode, move
Switch 1 to Menu Mode or OPEN position,
then press the ZERO key repeatedly until…
CONF is displayed.
2. Press the UNITS key…
FILT is displayed. This stands for filter-
ing.
3. Press the UNITS key…
The current setting, FAST or SLO, is
displayed.
10
Configuration Mode
Step-by-Step
Instructions for
CONF Mode