Spare parts list – Salter Brecknell 7821 User Manual
Page 23
Model 7821 Bench Scale User’s Manual
23
Spare Parts List
Description
Part Number
Keyboard Panel
1163-15803
Display PCB
7405-15465
Loadcell (100kg)
7154-16335-100
Main PCB
7405-14704-2
Power Supply
1148-15536
RS-232 Cable
1140-13842
1. Verify that the weigh platter is on the scale.
2. Press the ZERO key.
3. Power down, then power up the scale.
4. Recalibrate the scale.
1. Remove all weight from the scale.
2. Press the ZERO key.
3. Power down, then power up the scale.
4. Recalibrate the scale.
1. Check cable connection at both the rear of
the scale and the host device.
2. Check communication setting and baud rate
on both scale and host device.
3. Perform I/O loopback test.
4. Replace main PCB.
1. Replace display panel.
2. Replace display PCB.
3. Replace main PCB.
Display shows center
“ – – – – ” dashes
(indicates the scale is
outside zero capacity of
±2%).
Display shows upper
“ – – – – ” dashes
(indicates the scale is
over capacity).
Scale is not
transmitting data to the
host device
The ZERO key and TEST
key do not function.