beautypg.com

Spare parts list – Salter Brecknell 7821 User Manual

Page 23

background image

Model 7821 Bench Scale User’s Manual

23

Spare Parts List

Description

Part Number

Keyboard Panel

1163-15803

Display PCB

7405-15465

Loadcell (100kg)

7154-16335-100

Main PCB

7405-14704-2

Power Supply

1148-15536

RS-232 Cable

1140-13842

1. Verify that the weigh platter is on the scale.

2. Press the ZERO key.

3. Power down, then power up the scale.

4. Recalibrate the scale.

1. Remove all weight from the scale.

2. Press the ZERO key.

3. Power down, then power up the scale.

4. Recalibrate the scale.

1. Check cable connection at both the rear of

the scale and the host device.

2. Check communication setting and baud rate

on both scale and host device.

3. Perform I/O loopback test.

4. Replace main PCB.

1. Replace display panel.

2. Replace display PCB.

3. Replace main PCB.

Display shows center

“ – – – – ” dashes

(indicates the scale is

outside zero capacity of

±2%).

Display shows upper

“ – – – – ” dashes

(indicates the scale is

over capacity).

Scale is not

transmitting data to the

host device

The ZERO key and TEST