Model 7815 Parcel Bench Scale User’s Manual

19

Factory default settings: 9600 baud, 7 data bits,
even parity, 1 stop bit. Protocol is NCI standard
only.

Standard 9-pin pass through RS-232 interface
cable included. Not a null modem.

Symbol Key:

End of Text Character (03 hex)

Line Feed Character (0A hex)

Carriage Return Character (0D hex)

Space (20 hex)

X

Character from display including
minus sign

hh

Two status bytes

uu

Unit of measure (lb, kg) using ANSI
standard abbreviations)

Communication Setting

Command Scale Response

Results

W

xxxx.xxuu

Returns decimal

hh

weight with units

or

and scale status.

Returns contents

hh

of display (other
than wt) and scale
status

S

hh

Returns scale
status

Z

hh

Scale is zeroed,
then status returns

All else

?

Unrecognized