Configuration mode – Salter Brecknell 7815 / 7815R User Manual
Page 12
Model 7815 Parcel Bench Scale User’s Manual
12
Configuration Mode
Step-by-Step Instructions
for CONF Mode
Return to normal
operating mode by
pressing the SW-1
switch.
The configuration (CONF) mode menu lets you
configure the scale to your specific application.
The items you can configure are as follows:
FILT (FILTER) – Adjusts the scale’s response to
fit environment. Factory default setting is FAST.
BAUD (BAUD) – Allows selection of appropriate
baud rate and parity for computer interface.
Factory default setting is 96-E.
1. Press SW-1. . .
DIAG is displayed.
2. Press the ZERO key. . .
CONF is displayed.
3. Press the TEST key. . .
FILT is displayed.
4. Press the TEST key. . .
The present filter setting is displayed.
The two choices are FAST and SLO.
When the proper selection
7. Press the TEST key to perform this test…
Indicates internal A/D raw count. When
weight is applied, the count value should
increase proportionately.
8. Press the TEST key to stop the test . . .
The remaining selections are for viewing
current settings only. You can scroll
through the menu to verify the settings,
but to make changes, you must enter
configuration or calibration.