beautypg.com

Configuration mode – Salter Brecknell 6720 User Manual

Page 17

background image

Model 6700 Family User’s Manual

17

The Configuration (CONF) Mode menu allows
scale configuration for your specific application
needs. The items you can configure are as
follows:

FILTERING (FILT) – Choose between FAST
and SLO filtering. SLO should be chosen in
areas susceptible to vibration. Choose FAST
filtering for more stable conditions.

Baud (BAUD) – Choose a baud and parity from
Table 2.

Protocol (PROT) – Select the RS-232 commu-
nication protocol.

NCI – NCI standard
ECR – Cash register compatible
8213 – 8213 compatible (Sharp)
2250 – 2250 compatible (Swintec)
TEC – MA-1535/1595 compatible (TEC)*
ATT – AT&T compatible
o4000 – Olympia Cash Register compatible

* Approved for use with 30 and 60 lb or 7, 15, 30 and
60 kg capacities only

Access the Menu mode as shown in Figure 3.

1.

From the DIAG display, press the ZERO key
until CONF is displayed, or from the normal
weighing mode, move Switch 1 to the Menu
mode or the OPEN position; then press the
ZERO key until CONF is displayed.

Configuration Mode

26. When you are finished, press the ZERO

key, until DONE is displayed, then press the
TEST key to return to the top menu level…

DIAG is displayed. Or close Switch 1 to
return to normal weighing mode.

This manual is related to the following products: