B140 Counting Scale User Instructions
5.6 Set Scale’s ID
Set the scale’s ID by following these instructions:
1.
In normal working mode, hold the ON/OFF and PLU6 keys at the same time
until …
SEtUP is displayed in the PIECE WEIGHT window.
id (ID) is displayed in the COUNT window.
xxxxxx is displayed in the WEIGHT window. This means that the scale’s
ID is currently set to xxxxx.
2.
Use the numeric keys to change the scale’s ID and press the Enter key save
the setting …
The scale returns to normal mode.
5.7 Displayed Messages
Below are the screen messages you may see during operation of this scale and what
they mean.
Err01
Scale overloaded
– – – – – –
Too many accumulations or accumulated counts too high
Err03
Weight signal is too small
Err04
The zero point is too high
Err05
The zero point is too low
Err12
The setting parameter(s) is not in normal range, or the parameter
has not been set
CAL.Err
There is an error in calibration: maybe the loaded weight is too
small or the input weight is not correct.
Err30
Input signal of ADC is over max. range
Err31
Input signal of ADC is below min. range
CAP
Displaying data relating to capacity
UoL
Displaying data relating to voltage
Add
The accumulated data
PC.t
Data about piece weight
SPL.PCS
Data about sample pieces
uP.PCS
Data about upper limit pieces
Lo.PCS
Data about lower limit pieces
unLd
Unload weight on the platter
InP.Ld
Input loaded weight’s number
CAL.oN
Calibration enable switch is ON
CAL.oFF
Calibration enable switch is OFF
ERR01
Displayed data is over 999999 or down -99999 (not include
decimal point)