5 error messages – Salter Brecknell CB100 User Manual
Page 7

2.
Press the PCS key to increment the number. When the timer setting
you want is displayed, press the TARE key…
The value stops flashing and the value is stored in memory.
3.
Press the ON/OFF key…
The scale restarts and returns to normal weighing mode.
1.5 Error Messages
Following are error messages which may be displayed, their
cause and solutions.
Display
Problem
Solution
A.ch.Er
Analog error
Recalibrate the scale
0¯
Problem with calibration
Recalibrate the scale
¯
Problem with calibration
Recalibrate the scale
_
Problem with calibration
Recalibrate the scale
0¯ ¯ ¯ ¯
Zero point is too large
Rezero or recalibrate the scale
EEP.Er
EPROM error
Contact your dealer
- - - - -
Weight is over 100.09g
Remove some of the weight
_ _ _ _ _
Input signal is too small
Rezero or recalibrate
PC.Er
Unit weight is less than 1 division
Add weight
- PB500 (4 pages)
- PB250 (12 pages)
- MB2610 (4 pages)
- MBS Series (14 pages)
- 302BP (6 pages)
- 304BP (26 pages)
- 308BP (27 pages)
- APD-100 (36 pages)
- ESA Series (14 pages)
- LPS30 (18 pages)
- PC150 (13 pages)
- SP60 (9 pages)
- 3700LP (20 pages)
- C3235 (16 pages)
- C3255 (18 pages)
- C3225 (40 pages)
- B140 (32 pages)
- B120 (19 pages)
- B130 (22 pages)
- 610 (23 pages)
- 630 (24 pages)
- 650 (43 pages)
- B220 (24 pages)
- B225 (44 pages)
- CS Series Crane (12 pages)
- 3800LP Series Calibrated with SBI-505 LED Indicator (22 pages)
- 405 (12 pages)
- LPS150 (30 pages)
- GP100 (13 pages)
- S100 (17 pages)
- PS150 (15 pages)
- S122 (63 pages)
- 6702 (28 pages)
- 6712 (24 pages)
- PS250 (28 pages)
- PS500 (19 pages)
- PS1000 (38 pages)
- PS3000HD (18 pages)
- SBI140 (35 pages)
- SBI100 (34 pages)
- SBI-521 (82 pages)
- 200 Series (47 pages)
- 200SL (2 pages)
- 400ES (30 pages)