De-Noise: De-Noise can remove or lower unwanted noise and preserve fine details and
edges.

ICR: ICR stands for IR Cut Filter Removable that is to estimate the intensity of the light and
switch the IP camera into the Day or Night mode. The function can set to automatically or
setting estimate value manually.

Current Value: The current Intensity value of the light. The red mark on the scroll bar

represents the current value of light‟s intensity.

Night Mode Threshold: Set a threshold value for IP camera to switch to Night mode.

The darker gray mark on the scroll bar represents the Night Mode Threshold value.

Day Mode Threshold: Set a threshold value for IP camera to switch to Day mode. The

lighter gray mark on scroll bar represents the Day Mode Threshold value.

[Note] 1. When the Current Value is great than Day Mode Threshold value, the IP camera

will switch to Day mode.

2. When the Current Value is less than Night Mode Threshold value, the IP camera

will switch to Night mode.

3. When the Current Value is between Night and Day Mode Threshold value, the

IP camera will stay in current mode.

Delay Time: A time gap period before mode switching.

Default Settings: Set all value back to factory default values.

PTZ Setting

[Note] If user needs to change these parameters, please check and set value properly for both,
network module and P/T scanner.

Camera Protocol: This device can connect to a PTZ camera or speed dome camera and
controls them thru RS485 interface.

Camera Address: This is the camera ID set in PTZ camera or speed dome camera.
[Note]
Please DO NOT changes the default value if unnecessary. If so, user needs to check
and set value properly for both sides.

Baud rate: This is the communication speed between network module and P/T scanner.