Sony CCD-TR61 User Manual
Page 47
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Symptom
Cause
Corrective Actions
page
The image on the
viewfinder screen is not
clear.
The viewfinder lens is
not adjusted.
Adjust the viewfinder lens.
14
A vertical band appears
when a subject such as
lights or a candle flame
Is shot against a dark
background.
The contrast between
the subject and
background is too high.
The camcorder Is not
malfunctioning.
Change locations.
—
t
1
The color of the
playback picture is not
appropriate.
A PROGRAM AE mode
is selected.
Set PROGRAM AE to the green
position.
29
a.
The playback picture is
not clear.
The EDIT switch is set in
the direction of the
arrow.
Set it in the opposite direction of
the arrow.
33
The channel or input for
the camcorder is not
selected on the TV.
Make the correct.
22
The picture is "noisy".
The video heads may be
dirty.
Clean the heads using the Sony
V8-2SCLH cleaning cassette.
34
When you adjust the
clock while viewing the
picture on the connected
TV, the area name and
area number do not
appear on the screen.
The DATA SCREEN-
/DISPLAY function is
turned off.
Press DATA SCREEN/DISPLAY
on the Remote Commander.
24
The supplied Remote
Commander does not
work.
The REMOTE
COMMANDER switch is
set to OFF.
Set it to ON.
43
Something interrupts the
infrared rays.
Remove the obstacles.
—
1
The lithium battery is not
inserted with the correct
polarity.
Insert the lithium battery with the
correct polarity.
11
The lithium battery is
dead.
Insert a new one.
11
The HOLD switch is
working.
Set the switch in the opposite
direction of the arrow.
43
There is dust in the
viewfinder.
—
Remove the viewfinder barrel
and clean the viewfinder screen
or viewfinder lens.
35
There is dust inside the
WIDE ANGLE.
—
Remove the dust by using the
blower.
35
O
c
2
9
O