Verifying power supply operation – Cisco ASR 1004 User Manual
Page 20

20
Step 8
Connect the other ends of the terminal block cables to the site ground connection. Move the circuit-breaker switch to
the On position (|).
This completes the procedure for connecting DC-input power. Your installation is complete. Proceed to the
Note
After powering off the router, wait a minimum of 30 seconds before powering it on again.
Verifying Power Supply Operation
Follow this procedure to verify power supply is operating correctly.
Step 1
Check that the power supply LEDs are:
•
INPUT OK is green
•
FAN OK is green
•
OUTPUT FAILED is not illuminated
Step 2
To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco
ASR1004 router. The other Cisco ASR1000 routers display similar type of output.
MCP_SCAL_R1#sho plat
Chassis type: ASR1004
The following output displays:
MCP_SCAL_R1#
If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for
assistance or additional instructions.
Slot
Type
State
Insert Time
1
ASR1000-SIP10 ok
00:03:19
1/1
SPA-8X1GE-V2
ok
00:02:23
2
ASR1000-SIP10
ok
00:03:19
2/0
SPA-1X10GE-L-V2
ok
00:02:22
2/1
SPA-8X1GE-V2 ok
00:02:17
R0
ASR1000-RP1
ok,active
00:03:19
F0
ASR1000-ESP20
ok,active
00:03:19
P0
ASR1004-PWR-AC
ok
00:02:50
P1
ASR1004-PWR-AC
ps, fail
00:02:50
Slot
CPLD Version
Firmware
Version
1
07091401
12.2(33r)XN2
2
07091401
12.2(33r)XN2
R0
08060301
12.2(0:0)
F0
08041102
12.2(33r)XN2