beautypg.com

Installing the dc ground lugs – Cisco ASR 1004 User Manual

Page 17

background image

17

Figure 10

shows the DC power supply for the Cisco ASR 1004 Router.

DC Power Supply for the Cisco ASR 1004 Router

Note

Shielded cables must be used to connect to the DB-25 alarm connector on both the AC and DC power supplies, in order
to comply with FCC/EN55022/CISPR22 Class A emissions requirements.

The Cisco ASR1004 has two of the same type power supplies in power supply Slot 0 and power supply Slot 1.

Caution

Before you connect DC-input power, you must install the DC power ground leads to the DC power supply.

Caution

To make sure that the equipment is reliably connected to earth ground, follow the grounding procedure
instructions.

Obtain these necessary tools and equipment:

Number 2 Phillips screwdriver

A 3/16-inch flat-blade screwdriver

Installing the DC Ground Lugs

To install the grounding lugs on the DC power supply, follow these instructions.

Figure 11

shows the location of the DC power

supply grounding stud.

1

DC power supply terminal block and plastic cover

5

DC power supply earth ground symbol

2

DC power supply LEDs

6

DC power supply On (I)/ Off (O)

3

DB-25 alarm connector

7

DC power supply handle

4

DC power supply fan

280185

OUTPUT INPUT

FAIL

OK

OK

FAN

60V
1A MAX

OUTPUT INPUT

FAIL

OK

OK

FAN

60V
1A MAX

1

2

3

4

5

6

7