beautypg.com

Connect dc power to the router – Cisco ASR 1004 User Manual

Page 15

background image

15

Step 2

Tighten the captive installation screws.

Step 3

Insert the AC power cable into the power supply inlet.

Step 4

Plug the power supply cable into the power source.

Step 5

The power supply LEDs light when power is supplied to the router.

Figure 10

Cisco ASR 1004 Router AC Power Supply

Note

Shielded cables must be used to connect to the DB-25 alarm connector on both the AC and DC power supplies, in order
to comply with FCC/EN55022/CISPR22 Class A emissions requirements.

Step 6

Turn the power supply Standby switch to On (|) position.

This completes the procedure for connecting AC-input power.

Connect DC Power to the Router

This section provides instructions for installing the DC power supply into the Cisco ASR 1004 Router. Read the safety warnings
and important notices before you begin.

Warning

Installation of the equipment must comply with local and national electrical codes. Statement 1074

Warning

Never install an AC power module and a DC power module in the same chassis. Statement 1050

1

AC power supply Standby switch

4

AC power supply fan

2

AC power supply LEDs

5

AC power inlet

3

DB-25 Alarm connector

6

AC power supply handle

280184

OUTPUT INPUT

FAIL

OK

OK

FAN

100V-240V~ 12A-5A

50-60Hz

ALARMS
60V
1A MAX

OUTPUT INPUT

FAIL

OK

OK

FAN

100V-240V~ 12A-5A

50-60Hz

ALARMS
60V
1A MAX

1

2

3

4

6

5