beautypg.com

Program checks – Crestron electronic infiNET EX CEN-RFGWX-EX User Manual

Page 26

background image

InfiNET EX™ Gateway

Crestron CEN-RFGW-EX

Upgrade CEN-RFGW-EX firmware via Crestron Toolbox.

• Establish communication with the CEN-RFGW-EX and display

the “System Info” window.

• Select Functions | Firmware… to upgrade the CEN-RFGW-EX

firmware.

Program Checks

Actions that can be performed on the CEN-RFGW-EX vary depending
on whether it is connected via Cresnet or Ethernet.

Cresnet
Connections

For Cresnet connections, using Crestron Toolbox, display the network
device tree (Tools | Network Device Tree) to show all network devices
connected to the control system. Right-click on the CEN-RFGW-EX to
display actions that can be performed on the CEN-RFGW-EX.

Ethernet
Connections

For Ethernet connections, display the “System Info window (click the

icon) and select the Functions menu to display actions that can be

performed on the CEN-RFGW-EX.
Be sure to use Crestron Toolbox to create the CEN-RFGW-EX IP table.

• Select Functions | IP Table Setup.
• Add, modify or delete entries in the IP table. The CEN-RFGW-EX

can have only one IP table entry.

• A defined IP table can be saved to a file or sent to the device.

Edit the control system’s IP table to include an entry for the
CEN-RFGW-EX. The entry should list the CEN-RFGW-EX’s IP ID
(specified on the CEN-RFGW-EX’s IP table) and the internal gateway IP
address 127.0.0.1.

NOTE: Only one IP table entry is allowed. The unit can talk to only one
processor over IP.

22

infiNET EX™ Gateway: CEN-RFGW-EX Operations & Installation Guide – DOC. 6706A