beautypg.com

Power-supply service data, Hard-disk drive for the mini tower computer -23, Hard-disk drive for the optiplex nx1 computer -23 – Dell OptiPlex NX1 User Manual

Page 35: Power-supply service data -23, Table 1-4, Optiplex gx1/gx1p dc voltage ranges -23, 3rzhu6xsso\6huylfh'dwd, Dug'lvn'ulyhiruwkh0lql7rzhu&rpsxwhu, Dug'lvn'ulyhiruwkh2swl3oh[1;&rpsxwhu

background image

System Overview

1-23

+DUG'LVN'ULYHIRUWKH0LQL7RZHU&RPSXWHU

The hard-disk drive bracket is located beneath the externally accessible drive
bays at the front of the computer. The hard-disk drive bracket can contain
either one or two 1-inch-high EIDE or SCSI hard-disk drives, or one 1-inch-high
EIDE or SCSI hard-disk drive and one 1.6-inch-high EIDE or SCSI hard-disk
drive.

+DUG'LVN'ULYHIRUWKH2SWL3OH[1;&RPSXWHU

One 1-inch-high EIDE hard-disk drive can be mounted to the top of the
expansion-card cage.

3RZHU6XSSO\6HUYLFH'DWD

The low-profile computers have a 145-W system power supply, the midsize
computers have a 200-W system power supply, and the mini tower computers
have a 230-W power supply. All system power supplies can operate from an
AC power source of 115 VAC at 50 to 60 Hz or 230 VAC at 50 to 60 Hz.

:$51,1* 7KH YROWDJH VHOHFWLRQ VZLWFK ORFDWHG RQ WKH EDFN RI WKH

SRZHU VXSSO\ DVVHPEO\ PXVW EH VHW WR WKH FRUUHFW RSHUDWLQJ YROWDJH

RU 9 EHIRUH \RX SOXJ WKH SRZHU FDEOH LQWR DQ HOHFWULFDO

RXWOHW

The system power supply provides the DC operating voltages and currents
listed in Table 1-4.

NOTE: The power supply produces DC voltages only under its loaded condi-
tion. Therefore, when you measure these voltages, the DC power input
connectors must be connected to their corresponding power input connectors
on the system board or drives.

7DEOH 2SWL3OH[ *;*;S '& 9ROWDJH 5DQJHV

9ROWDJH

5DQJH

0D[LPXP 2XWSXW &XUUHQW

+3.3 VDC

+3.15 to +3.45 VDC

12.0 A

1

(low-profile computers);

14.0 A

1

(midsize and mini tower

computers)

+5 VDC

+4.75 to +5.25 VDC

18.0 A

1

(low-profile computers);

22.0 A

1

(midsize and mini tower

computers)

+12 VDC

+11.40 to +12.60 VDC

3.0 A

2

(low-profile computers);

6.0 A

2

(midsize and mini tower

computers)

1

The combined load on the +5-VDC and +3.3-VDC outputs should not exceed 105 W on

the low-profile computers or 140 W on the midsize/mini tower computers.

2