Power-supply service data, Hard-disk drive for the mini tower computer -23, Hard-disk drive for the optiplex nx1 computer -23 – Dell OptiPlex NX1 User Manual
Page 35: Power-supply service data -23, Table 1-4, Optiplex gx1/gx1p dc voltage ranges -23, 3rzhu6xsso\6huylfh'dwd, Dug'lvn'ulyhiruwkh0lql7rzhu&rpsxwhu, Dug'lvn'ulyhiruwkh2swl3oh[1;&rpsxwhu
System Overview
1-23
+DUG'LVN'ULYHIRUWKH0LQL7RZHU&RPSXWHU
The hard-disk drive bracket is located beneath the externally accessible drive
bays at the front of the computer. The hard-disk drive bracket can contain
either one or two 1-inch-high EIDE or SCSI hard-disk drives, or one 1-inch-high
EIDE or SCSI hard-disk drive and one 1.6-inch-high EIDE or SCSI hard-disk
drive.
+DUG'LVN'ULYHIRUWKH2SWL3OH[1;&RPSXWHU
One 1-inch-high EIDE hard-disk drive can be mounted to the top of the
expansion-card cage.
3RZHU6XSSO\6HUYLFH'DWD
The low-profile computers have a 145-W system power supply, the midsize
computers have a 200-W system power supply, and the mini tower computers
have a 230-W power supply. All system power supplies can operate from an
AC power source of 115 VAC at 50 to 60 Hz or 230 VAC at 50 to 60 Hz.
:$51,1* 7KH YROWDJH VHOHFWLRQ VZLWFK ORFDWHG RQ WKH EDFN RI WKH
SRZHU VXSSO\ DVVHPEO\ PXVW EH VHW WR WKH FRUUHFW RSHUDWLQJ YROWDJH
RU 9 EHIRUH \RX SOXJ WKH SRZHU FDEOH LQWR DQ HOHFWULFDO
RXWOHW
The system power supply provides the DC operating voltages and currents
listed in Table 1-4.
NOTE: The power supply produces DC voltages only under its loaded condi-
tion. Therefore, when you measure these voltages, the DC power input
connectors must be connected to their corresponding power input connectors
on the system board or drives.
7DEOH 2SWL3OH[ *;*;S '& 9ROWDJH 5DQJHV
9ROWDJH
5DQJH
0D[LPXP 2XWSXW &XUUHQW
+3.3 VDC
+3.15 to +3.45 VDC
12.0 A
1
(low-profile computers);
14.0 A
1
(midsize and mini tower
computers)
+5 VDC
+4.75 to +5.25 VDC
18.0 A
1
(low-profile computers);
22.0 A
1
(midsize and mini tower
computers)
+12 VDC
+11.40 to +12.60 VDC
3.0 A
2
(low-profile computers);
6.0 A
2
(midsize and mini tower
computers)
1
The combined load on the +5-VDC and +3.3-VDC outputs should not exceed 105 W on
the low-profile computers or 140 W on the midsize/mini tower computers.
2