Conclusion, Table 7, Recommended bios setting – Dell PowerEdge 1655MC User Manual
Page 26

Optimal BIOS settings for HPC with Dell PowerEdge 12
th
generation servers
26
shows the performance improvement with the new cluster relative to the previous generation. The
secondary y-axis plots the energy efficiency of the new cluster relative to the earlier one.
The results are impressive. HPL performance is 3.6 times (3.6x) better with the latest generation and
2.93 times more energy efficient. Fluent and WRF also demonstrate a significant improvement with the
new servers. For applications that are similar to LU, the two generations perform similarly. While
comparing energy efficiency, recall that the 12
th
generation cluster uses processors that are a higher
wattage than the 11
th
generation cluster (130W versus 95W).
7. Conclusion
The goal of this white paper is to provide quantitative data on the impact of different PowerEdge BIOS
options on the performance and energy efficiency of HPC applications. Unique to this study is the
emphasis not just on performance but also power consumption and energy efficiency, and the focus on
a cluster-level study as opposed to a single-server evaluation.
Table 7. Recommended BIOS setting
Balanced
configuration
Performance
focused
Energy Efficient
configuration
Latency
sensitive
10
System Profile
Performance Per
Watt Optimized
(DAPC)
Performance
Optimized
Performance Per
Watt Optimized
(DAPC)
Custom
CPU Power
Management
System DBPM
Max
Performance
System DBPM
Max
Performance
Memory
Frequency
Max
Performance
Max
Performance
Max Performance
Max
Performance
Turbo Boost
Enabled
Enabled
Disabled
Disabled
C States
Enabled
Disabled
Enabled
Disabled
C1E
Enabled
Disabled
Enabled
Disabled
Monitor/ Mwait
Enabled
Enabled
Enabled
Disabled
Logical
Processor
Disabled
Disabled
Disabled
Disabled
Node
Interleaving
Disabled
Disabled
Disabled
Disabled
* The text in gray indicates options that are pre-selected by the System Profile and cannot be tuned individually.
Text in black indicates options that should be explicitly configured.
Dell PowerEdge 12
th
generation servers have an enhanced BIOS that provides several options that can
be tuned to suit specific needs. This white paper evaluates some of these BIOS tuning parameters and
provides specific recommendations on the best settings for HPC applications.