beautypg.com

Dell POWEREDGE M905 User Manual

Page 67

background image

About Your System

67

Table 1-18.

Blade Messages

Message

Causes

Corrective Actions

Alert: DIMM_

n

and

DIMM_

n

must be

populated with a

matched set of

DIMMs if more than

1 DIMM is present.

The following

memory DIMMs have

been disabled.

The installed memory
configuration is invalid.

Ensure that the memory
modules are installed in
matched pairs. See "System
Memory" on page 105.

Alert! Node

Interleaving

disabled! Memory

configuration does

not support Node

Interleaving.

The installed memory
configuration does not
support node interleaving.

Install a memory
configuration that supports
node interleaving. See
"System Memory" on
page 105.

Alert! Redundant

memory disabled!

Memory

configuration does

not support

redundant memory.

The installed memory
configuration does not
support redundant
memory.

Install a memory
configuration that supports
redundant memory. See
"System Memory" on
page 105.

Disable the Redundant
Memory option in the
System Setup program. See
"Using the System Setup
Program" on page 79.

Alert! Redundancy

was previously

lost. Power cycle

required to

reconfigure

redundant memory.

Memory error.

Power cycle the blade.