beautypg.com

45 b. emergency operation methods – Cleveland Range The MINI OES-6.08 User Manual

Page 51

background image

45

B. Emergency Operation Methods

X: Operation possible
–: Operation not possible

Error

Message on display

OES

Steam

Combi

Hot

Air

Retherm

Cook

&

Hold

Delta-

T

E01

Not enough water

X

--

--

up to

356°F

--

X

X

E02

Connection area temp.

too high

X

X

up to 284°F

up to

284°F

up to

284°F

up to

284°F

up to

284°F

E04

Connection area fan

malfunction

X

X

up to 284°F

up to

284°F

up to

284°F

up to

284°F

up to

284°F

E11

Excess oven

temperature

--

--

--

--

--

--

--

E15

Excess temperature of

condenser

X

--

--

up to

356°F

--

X

X

E33

Core temp. sensor

faulty

X

X

X

X

X

X

X

E36

Condenser sensor

failure

X

X

(2)

up to 356°F

(2)

up to

356°F

(2)

up to

356°F

(2)

X

(2)

X (2)

E 29

Error in ground

connection

--

--

--

--

--

--

--

E80

ID error

--

--

--

--

--

--

--

E81

Program memory error

X

X

X

X

X

X

X

E82

Working parameter

error

X

X

X

X

X

X

X

E83

Algo. error

X

X

X

X

X

X

X

E89

I2C error

X

X

X

X

X

X

X

NOTES:

1)

Cooking time will be much longer, dishes in upper levels will be ready first

2)

Injection of water into condenser constantly activated (higher water consumption)

3)

Errors E23 and E26 simultaneously, steam generator is not pre-heated