45 b. emergency operation methods – Cleveland Range The MINI OES-6.08 User Manual
Page 51
45
B. Emergency Operation Methods
X: Operation possible
–: Operation not possible
Error
Message on display
OES
Steam
Combi
Hot
Air
Retherm
Cook
&
Hold
Delta-
T
E01
Not enough water
X
--
--
up to
356°F
--
X
X
E02
Connection area temp.
too high
X
X
up to 284°F
up to
284°F
up to
284°F
up to
284°F
up to
284°F
E04
Connection area fan
malfunction
X
X
up to 284°F
up to
284°F
up to
284°F
up to
284°F
up to
284°F
E11
Excess oven
temperature
--
--
--
--
--
--
--
E15
Excess temperature of
condenser
X
--
--
up to
356°F
--
X
X
E33
Core temp. sensor
faulty
X
X
X
X
X
X
X
E36
Condenser sensor
failure
X
X
(2)
up to 356°F
(2)
up to
356°F
(2)
up to
356°F
(2)
X
(2)
X (2)
E 29
Error in ground
connection
--
--
--
--
--
--
--
E80
ID error
--
--
--
--
--
--
--
E81
Program memory error
X
X
X
X
X
X
X
E82
Working parameter
error
X
X
X
X
X
X
X
E83
Algo. error
X
X
X
X
X
X
X
E89
I2C error
X
X
X
X
X
X
X
NOTES:
1)
Cooking time will be much longer, dishes in upper levels will be ready first
2)
Injection of water into condenser constantly activated (higher water consumption)
3)
Errors E23 and E26 simultaneously, steam generator is not pre-heated