SCSI Commands

Page Control (PC) - This field indicates the type of mode page parameter values to return as shown in the
following table

Page Code - This field determines which pages should be reported. For a list of available mode pages, see

Table 36

on page 37.

Allocation Length - This field specifies the number of bytes that the initiator allocated for returned MODE
SENSE data. A length of 0 means that the library will return no MODE SENSE data. This is not considered
to be an error.

Mode Sense (6) Response

The six-byte MODE SENSE response consists of a single four-byte Mode Parameter Header, followed by
zero or more mode pages. Each page is individually described in “Mode Pages.”

Mode Parameter Header

The following table lists the format of the Mode Parameter Header for the six-byte MODE SENSE command.

Mode Data Length - This specifies the length in bytes that is available to be transferred as part of the
response. The Mode Data Length does not include itself but does include the remaining 3 bytes of the
parameter header, as well as the overall total number of bytes being sent for all requested pages.

Table 31

Page Control (PC) field

Page Control

Description

0

0

Report current values defined by:

• The values set by the last successful MODE SELECT command.

• The default values if no saved values exist.

0

1

Report changeable values

1

0

Report default values

1

1

Report saved values (report default values if no pages are previously saved)

Table 32

Mode Parameter Header format for Mode Sense (6)

Bit

Byte

7

6

5

4

3

2

1

0

0

Mode Data Length

1

Reserved

2

Reserved

3

Reserved