Mode Select (10) - 55h

What the Library Does With This Command

The library does not support any changeable parameters, and this command is supported for compatibility
only. This command can only be issued to the Controller logical unit.

Libraries without DA blades do not support this command.

Command Usage

A MODE SENSE command with the PC field set to 1h and the Page Code field set to 3Fh can be issued
before the MODE SELECT command is issued to determine which mode parameters are supported, which
mode parameters are changeable, and the supported length of each page. Since the library does not
support any changeable parameters, use of MODE SELECT provides limited value. For a list of available
mode pages, see

Table 36

on page 37.

Mode Select (10) CDB Format

The ten-byte MODE SELECT CDB format is shown in the following table.

Page Format (PF) - This bit indicates that the data sent by the initiator after the MODE SELECT header
and block descriptors complies with the definition of pages in the SCSI standard. The value must be set to 1.

Save Parameters (SP) - Savable pages are not supported and this field must be set to 0.

Parameter List Length - This field specifies the number of bytes that will be transferred for the MODE
SELECT parameter list, and should be equal to the length of a single Parameter List Header plus the lengths
of all pages to be transferred. A length of zero indicates that no data is transferred. This is not considered
to be an error.

Table 28

MODE SELECT CDB format

Bit

Byte

7

6

5

4

3

2

1

0

0

Op Code (55h)

1

Logical Unit Number

PF

Reserved

SP

2

Reserved

3

Reserved

4

Reserved

5

Reserved

6

Reserved

7

Parameter List Length

8

9

Control