Weight and physical dimensions, Facility requirements – Dell PowerEdge M805 User Manual
Page 36
26
4424 Blade Server SAN I/O Module Hardware Reference Manual
53-0000571-01
Weight and physical dimensions
A
Weight and physical dimensions
lists the weight and physical dimensions of the SAN I/O Module.
Facility requirements
The information in
shows the operating and non-operating limitations of the Brocade 4424
SAN I/O Module.
TABLE 6
SAN I/O Module Specifications
Dimension
Measurements
Height
1.24 in (31.45 mm)
Width
10.74 in (272.75 mm)
Depth
12.08 in (306.74 mm)
Weight
3.84 (1.74 kg) — without media
TABLE 7
Environmental Requirements
Condition
Operating
Non-operating
Temperature
32°F to 122°F (0°C to 50°C)
-45.4°F to 163.4°F (-43°C to 73°C)
Humidity
10% to 95%, non-condensing at
84.2°F (29°C)
5% to 95%, non-condensing at
100.4 °F (38°C)
Altitude
Up to 10,000 ft (3,048 m)
40,000 ft (12,192m)
Shock
20G for 11ms
33G for 11ms
Vibration
Sine sweep: 1.0G at 5-500-5 Hz
for 15 minutes
Random: 0.5G at 5-500 Hz
for 60 minutes
Sine sweep; 2.4G at 5-500-5 Hz
for 15 minutes
Random: 1.12G at 5-500 Hz
for 30 minutes
Air flow
86 °F (30°C) Ambient: Approx. 3CFM
104°F (40°C) Ambient: Approx.
9CFM
None required