Dell PowerVault MD3800i User Manual
Page 53

3. Log on to the target:iscsicli PersistentLoginTarget
* * * * *
–
command to display the target list.
–
–
to.
–
–
more than one session to be logged in to a target at one time.
–
–
–
NOTE:
replaced with an asterisk (*) if CHAP is not used.
– Mapping_Count is 0, indicating that no mappings are specified and no further parameters are
required.
* * * An asterisk (*) represents the default value of a parameter. For example, your log on command
might look like this: iscsicli PersistentLoginTarget iqn.1984-
05.com.dell:powervault.6001372000ffe3332xx0000046 72edf2 3260 T
192.168.130.101 * * * 0x2 * * * * * * * * * 0.
To view active sessions to the target, run the following command: iscsicli SessionList.
To support storage array controller failover, the host server must be connected to at least one iSCSI
port on each controller. Repeat step 3 for each iSCSI port on the storage array that you want to
establish as a failover target. The Target_ Portal_Address is different for each port you connect to.
PersistentLoginTarget does not initiate a login to the target until after the system is rebooted. To
establish immediate login to the target, substitute LoginTarget for PersistentLoginTarget.
NOTE: See the Microsoft iSCSI Software Initiator 2.x User’s Guide for more information about
the commands used in the previous steps. For more information about Windows Server 2008
Server Core, see the Microsoft Developers Network (MSDN) at microsoft.com.
Connecting The Target Storage Array From The Host
Server Using Linux
In MDSM, the Configure iSCSI Host Ports displays the status of each iSCSI port you attempt to connect
and the configuration state of all IP addresses. If either displays Disconnected or Unconfigured,
respectively, check the following and repeat the iSCSI configuration steps:
• Are all cables securely attached to each port on the host server and storage array?
• Is TCP/IP correctly configured on all target host ports?
• Is CHAP set up correctly on both the host server and the storage array?
To review optimal network setup and configuration settings, see "Configuring iSCSI on Your Storage
Array".
53