Diagnostic port (d_port) – Dell POWEREDGE M1000E User Manual
Page 119

Fabric OS Troubleshooting and Diagnostics Guide
103
53-1002751-01
Diagnostic Port (D_Port)
10
Example
The following example shows the results of a portdporttest - -show output where the electrical and
optical tests pass but the link test fails.
switch:admin> portdporttest --show 10/39
D-Port Information:
===================
Slot:
10
Port:
39
Remote WWNN:
10:00:00:05:33:7e:69:c4
Remote port:
24
Mode:
Manual
No. of test frames:
12 Million
Test frame size:
1024 Bytes
Payload Pattern:
JTSPAT
FEC (enabled/option/active):
Yes/No/No
CR (enabled/option/active): No/No/No
Start time:
Mon Jan 16 05:57:51 2012
End time:
Mon Jan 16 05:58:56 2012
Status:
FAILED
================================================================================
Test
Start time
Result
EST(HH:MM:SS)
Comments
================================================================================
Electrical loopback05:57:52 PASSED
--------
----------
Optical loopback 05:58:06 PASSED
---------
---------
Link traffic test 05:58:13 FAILED
--------
See failure report
================================================================================
Roundtrip link latency:
934 nano-seconds
Estimated cable distance:
1 meters
Buffers required:
1 (for 1024 byte frames at 16Gbps speed)
Failure report:
Errors detected (local):
CRC, Bad_EOF, Enc_out
Errors detected (remote):
CRC, Bad_EOF
Please use portstatsshow and porterrshow for more details on the above errors.
Example
Use the portDportTest - -show all command to display the capabilities and test results of all the
D_Ports in a switch.
switch:admin> portdporttest --show all
Port State SFP Capabilities Test Result
=============================================
24 ONLINE E,O PASS
26 ONLINE E,O RESPONDER
33 OFFLINE --- RESPONDER