Considerations for downgrading firmware – Dell POWEREDGE M1000E User Manual

Page 73

background image

Fabric OS Troubleshooting and Diagnostics Guide

57

53-1002751-01

Considerations for downgrading firmware

5

Checking version compatibility...

Version compatibility check passed..

The following items must be addressed before downloading the specified

firmware:

FC8-32E and FC8-48E are not supported by the targeted firmware. Please use

slotshow to determine which of these are installed and remove them before

continuing.

The messages in this section are displayed if an exception case is encountered during firmware
downgrade. The following example shows feature-related messages that you may see if you were
downgrading from v7.1.0 to v6.4.x:

Downgrade is not allowed because one or more ports name length is greater than

32 bytes. Please use "portname" CLI to check and fix the port name/length

before downgrading.

Downgrade is not allowed because Device Based Routing is configured. Please

use "aptpolicy" to change the routing policy.

Downgrade is not allowed because Location ID is configured. Please use

"configure" command to clear Location ID.

Downgrade is not allowed because the existing zone configuration is more than

1MB. To downgrade to lower firmware version modify the existing zone

configuration to 1MB or lesser.

Downgrade is not allowed because switch is in AG mode and D-Ports are

configured.Please use "switchshow" to view the D-port list and use

"portcfgdport --disable " to disable it before downgrading.

Downgrade is not allowed because one or more ports have credit recovery

enabled. Please use "portcfgcreditrecovery --disable" command to disabled

credit recovery.

Auto CSCTL feature is enabled. If you are downgrading the firmware, please

disable the auto csctl mode using "configurechassis" command and following

that either perform powercycle on each non-CP blades or reboot the system

before performing firmwaredownload.

Downgrade is not allowed because one or more ports have FEC enabled. Please

use "portcfgfec --disable" command to disabled FEC.

The messages in this section are displayed if an exception case is encountered during firmware
downgrade. The following example shows feature-related messages that you may see if you were
downgrading from v7.1.0 to v7.0.x:

Downgrade to selected version is not allowed because few ports are configured

with Longdistance -buffers option. Please remove the configuration using

"portcfglongdistance L0" CLI or change the configuration with -distance

option.

Downgrade is not allowed because Location ID is configured. Please use

"configure" command to clear Location ID.

Downgrade is not allowed because switch is in AG mode and D-Ports are

configured. Please use "switchshow" to view the D-port list and use

"portcfgdport --disable " to disable it before downgrading.