Updating the shared hard drive firmware, Updating the cmc firmware, For more information, see – Dell PowerEdge VRTX User Manual
Page 11

22. Insert the shared storage hard drives that you had removed earlier. Insert the shared hard drives in
the original slots.
23. Turn on the PowerEdge VRTX system.
24. Confirm the Virtual Disk Layout and the Virtual Disk Assignments in the CMC GUI. If the virtual disks
are not imported, not present, or the virtual disk assignments are not present or wrong, contact Dell
Technical Support.
25. Turn off the PowerEdge VRTX system.
26. Insert the server modules that you had removed earlier. Insert the server modules in the original slots.
27. Turn on the PowerEdge VRTX system.
28. Turn on the server modules.
29. Configure multipath for the Windows operating system.
For information on multipath, see
Information about Configuring Multipath
.
Updating the Shared Hard Drive Firmware
Click Chassis Overview → Storage → Update and see if the shared hard drive firmware needs to be
updated. For the latest drivers and firmware versions, see dell.com/support/drivers.
1.
Log in to the CMC GUI by using the management station.
The Chassis Overview page is displayed.
2. Navigate to Storage in the left pane and click the Update tab in the right pane.
The Storage Component Update page is displayed.
3. In Select the Update Package, click Browse and select the shared hard drive firmware you
downloaded by following the steps in
Downloading Firmware and Drivers
4. Select the hard drive component or components and click Update.
5. If the upgrade is successful, the status of the page changes to the updated firmware.
Click Chassis Overview → Storage and check the firmware version to see if the process was successful.
Updating the CMC Firmware
NOTE: Screen captures of the application are only for reference. Updates may have been made to
the application after publication of this document.
11