INSTRUCTIONS FOR INSTALLING WALL MOUNTED STAR-GF

1. Check voltage on heater nameplate and STAR-GF to make cer-

tain voltages are the same. If voltages do not match, consult
factory.

2. The STAR-GF will provide ground fault protection for STAR

Radiant heaters. The number of heaters serviced by one (1)
STAR-GF is dependent on the number and length of the heat-
ing elements. See Table 2.

3. See Instruction Sheet PG434 (provided with heater) for

IMPORTANT INSTRUCTIONS and WIRING.

4. Using the STAR-GF as a template mark mounting holes on

wall. Use an anchoring method adequate to support the weight.

5. Wire between STAR-GF and heater, wire to terminal block.

Service entrance wiring to be made to contactor connectors.
For wire gage see Table 1 of PG434.

6. The ground fault sensor has been factory set at .03 Amps, DO

NOT CHANGE THE SETTING.

Table 2

Heater Model

Max. No. of Heaters

STAR-02A

6

STAR-05A

3

STAR-06A

2

STAR-14A

1

STAR-GF Mounting Dimensions

8-1/2"

6"

10-3/4"

10"

6"

3/4

3/4

5/16 Dia.

Tripped Indicator

Light is On

Is this the

initial

installation?

Is this the first

time heater is

used for the

season?

Is the set point of
the GF sensor set
at a value less than
.03 amps?

Did the problem
occur after
working properly
during part of this
heating season?

This condition indicates
at least one element is
about to fail.

Call Chromalox
Service Dept.
1 800-368-2493

Close cover.

Does the

heater

operate?

Does the heater

operate?

1. Replace all elements.
2. Flip toggle switch back
and forth, one time to
reset GF sensor.

Do you want to

reduce future

down time and

maintenance

costs?

1. Turn set point dial
clockwise to .03 amps.
2. Flip toggle switch mounted ontop
of enclosure back and forth one
time, (this resets the GF sensor).

Unbuss wiring, check insulation resistance
on each element.
1. Each element to have at least 10 Meg
terminal to sheath.
2. If element does not have at least 10 Meg.
dry out element by applying half of the
rated voltage for one hour.
3. Rebuss elements, re-energize heater, flip
toggle switch back and forth, one time
to reset GF sensor.

Does the heater

operate?

Call Chromalox
Service Dept.
1 800-368-2493

Does the

heater

operate?

Close cover.

Close cover.

Close cover.

Unbuss wiring, check insulation resistance
on each element.
1. Each element to have at least 10 Meg
terminal to sheath.
2. If element does not have at least 10 Meg.
dry out element by applying half of the
rated voltage for one hour.
3. Rebuss elements, re-energize heater, flip
toggle switch back and forth, one time
to reset GF sensor.

START

Yes

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

No

No

The Chromalox STAR-GF ground fault sensor provides a reli-

able and cost effective method for sensing ground faults. The pur-
pose is to monitor for ground faults, sense potential heater failure
symptoms and to protect equipment.

The current-carrying wires are routed through the current

transformer on the control. When ground current reaches the level
set by the trip point adjustment, (.03 Amps), the relay trips, illu-
minates the tripped LED and provides an output signal which de-
energizes the magnetic contactor.

ELECTRIC SHOCK HAZARD. Disconnect all power
to heater before installing or servicing kit(s).

Failure to do so could result in personal injury or
property damage. Kit(s) must be installed by a
qualified person in accordance with the National
Electrical Code, NFPA 70.

If heating element(s) fail to operate:

1. Open door of enclosure. DANGER: Hazard of Electric

Shock. If "Tripped" indicator is on, this indicates one or more
heating elements are about to fail. Disconnect power and fol-
low the GF Troubleshooting Diagram below.

2. If the "Tripped" indicator is not on, check for blown fuses or

failed components within the heater's electrical system.

MAINTENANCE

GF TROUBLESHOOTING DIAGRAM