Carrier 48SS036 User Manual

Page 2

background image

Date:

Supersedes:

48SS018, 024, 030, 036, 042, 048 & 060

STANDARD-EFFICIENCY

COMBINATION GAS HEATING/

ELECTRIC COOLING UNITS

48SS

Rev.:

-3SB

JOB DATA:

LOCATION:

BUYER:

BUYER P.O. #

CARRIER #

UNIT NUMBER:

MODEL NUMBER:

PERFORMANCE DATA CERTIFIED BY:

DATE:

ARI 210

ARI 270

DESCRIPTION

48SS units are standard-efficiency, one-piece gas heating electric cooling units,
pre-wired and pre-charged at the factory.

48SS units are convertible discharge units that can be used for either horizon-
tal or down discharge installations.

FEATURES

Standard one-year warranty.
Five-year Extended Protection Plan for the compressor.
Ten-year non-prorated warranty on heat exchanger.
Units are ‘‘Rated in accordance with ARI Standard No. 270 and
210/240.’’
Standard unit as factory assembled is design certified and listed by
UL and CSA.
Low temperature cooling operation standard to 40 F (4 C).
Hermetic compressor with internal linebreak and overload protec-
tion, self lubricating. Scroll compressors on 4 and 5 ton sizes.
Crankcase heater is standard on 024-042 3-phase units. (Not re-
quired on 018, 048 and 060 units.)
Indoor and outdoor coils constructed of aluminum fins mechan-
ically bonded to seamless copper tubes.
48SS units have single-stage cooling and heating.
Foil-faced cleanable insulation.
Sloped non-corrosive condensate drain pan.

Single-point gas connection.
Alternate electrical connections on opposite sides of unit.
Disconnect in accordance with NEC, must be field-supplied and
installed.
Multi-speed, direct drive indoor fan motor.
Weatherized cabinets. Heavy duty phosphated zinc-coated pre-
painted steel. Capable of withstanding 500-hour salt spray.
24-volt control circuit.
Heating controls include a direct spark ignition with flame
rectification. Fan switch, overtemperature switch, and flame roll-
out switch also included.
Induced-draft with hall effect sensor (to prove proper inducer draft
motor operation).
Alumaguard™ coated ‘‘Super-S’’ four-pass heat exchanger.
Integrated gas control board provides anti-cycle protection for gas
heat operation.
Base rail standard on all 3-phase units.

PERFORMANCE DATA

Operating Weight

lb (unit);

lb (curb)

COOLING
Net Total Capacity

Btuh

Net Sensible Capacity

Btuh

Compressor Power Input

kW

@

°F

Outdoor-Air Temperature

Indoor Entering Air db

°F

wb

°F

SEER/EER

CFM

Ext. Static Pressure

in. wg

Indoor Fan Motor

Hp

Rpm

Bhp

HEATING
Input

Btuh

Output

Btuh

AFUE

%

ELECTRICAL DATA

Power Supply to Unit

Volts

Phase

Hz.

Minimum Circuit Amps

Maximum Overcurrent Protection

ACCESSORIES AND OPTIONS

FACTORY-INSTALLED OPTIONS

Commercial Grade Base Rail

Dedicated Downshot/Base Rail

FIELD-INSTALLED ACCESSORIES

30% Open Manual Fresh Air Damper

Roof Curb:

Ⅺ 8Љ Height

Ⅺ 11Љ Height

Ⅺ 14Љ Height

One-in. Filter Rack

Crankcase Heater — Single Phase Only
(Required with 0° Low Ambient)

FIELD-INSTALLED ACCESSORIES (cont)

Ⅺ Programmable Electronic Thermostat

Ⅺ Thermostat and Subbase

Ⅺ 0° Low Ambient

Ⅺ Time Guard௡ II

Ⅺ L.P. Conversion Kit

Ⅺ Controls Upgrade Kit (High and

Low-Pressure Switch)

Ⅺ External Condensate Trap

Ⅺ Natural Gas High-Altitude Kit (2000-5000 ft

Above Sea Level)

2