Dell PowerEdge 6850 User Manual
Page 8
6
Information Update
E1000
FAIL SAFE
Failsafe event.
Capture the event log and
see "Getting Help" in your
Installation and Troubleshooting
Guide.
E1000
MISCONFIG
Missing or improperly installed
VRMs.
See "Installing a Processor VRM"
in your Installation
and Troubleshooting Guide. If the
VRMs appear to be properly
configured and installed, see
"Getting Help" in your
Installation and Troubleshooting
Guide.
E0119
TEMP AMBIENT
Ambient system temperature is
out of acceptable range.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
E0119
TEMP PROC #
The specified processor is out of
acceptable temperature range.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
E0119
TEMP PLANAR
System board temperature is out
of acceptable temperature range.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
E0212
PROC VTT
Processor VTT voltage is out
of acceptable voltage range.
See "Troubleshooting Power
Supplies" in your Installation
and Troubleshooting Guide.
E0212
VOLT PG n
System power supply is out of
acceptable voltage range; faulty
or improperly installed power
supply.
See "Troubleshooting Power
Supplies" in your Installation
and Troubleshooting Guide.
E0212
VOLT PG n Video
Video voltage is out of acceptable
voltage range.
See "Getting Help" in your
Installation and Troubleshooting
Guide.
E0212
VOLT BATT ROMB
Faulty RAID battery.
Replace the RAID battery.
See "Activating the Optional
Integrated RAID Controller"
in your Installation
and Troubleshooting Guide.
Table 1-2.
LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions