10

Information Update

E0880

PS REDUNDANCY
LOST

Power supply redundancy has
been lost because a power supply
has been removed from the
system.

Reinstall the power supply to
restore redundancy.

E0D76

BP DRIVE n

Faulty or improperly installed
hard drive or RAID controller.

See "Troubleshooting SCSI Hard
Drives," "Troubleshooting a RAID
Controller Card," and
"Troubleshooting the Integrated
RAID Controller" in your
Installation and Troubleshooting
Guide.

E0D76

SCSI CONNECTOR

SCSI cable is not connected.

See "Troubleshooting SCSI Hard
Drives" in your Installation
and Troubleshooting Guide.

EB107

PROC BUS PERR
PROC INIT ERR
PROC PROTOCOL
ERR

Faulty or improperly installed
microprocessor or system board.

See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide.

If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide.

EB107

PROC MACHINE CHK Faulty or improperly installed

microprocessor or system board.

See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide. If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide.

EB107

PROC HOT

Processor is out of acceptable
temperature range and has halted
operation.

See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.

EB10C

ECC UNCORR ERR

ECC UNCORR ERR
BANK #

Uncorrectable ECC errors have
occurred in system memory. The
affected memory bank may be
specified.

See "Troubleshooting System
Memory" in your Installation
and Troubleshooting Guide.

Table 1-2.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions