beautypg.com

Dell PowerEdge 6850 User Manual

Page 11

background image

Information Update

9

E07FA

PROC n THERMTRIP Specified microprocessor is out of

acceptable temperature range and
has halted operation.

See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide. If the problem persists,
ensure that the microprocessor
heat sinks are properly installed.
See "Removing a Processor" in
your Installation
and Troubleshooting Guide.

NOTE:

The LCD continues to

display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the Dell OpenManage
Baseboard Management
Controller User’s Guide for
information about these utilities.

E0876

PS n MISSING
PS n STATUS

No power available from the
specified power supply; specified
power supply is improperly
installed or faulty.

See "Troubleshooting Power
Supplies" in your Installation
and Troubleshooting Guide.

E0876

PS n PREDICTIVE

Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.

See "Troubleshooting Redundant
Power Supplies" in your
Installation and Troubleshooting
Guide.

E0876

PS n AC LOST
PS n AC RANGE

Power source for specified power
supply is unavailable, or out of
acceptable range.

Check the AC power source
for the specified power supply.

E0876

PS # AC OUT OF
RANGE - APPLY
200-240V

The AC power to the specified
power supply is out of operating
range.

Check the power source and
verify that it is supplying 215-
220V power. If the problem
persists, see "Getting Help"
in your Installation
and Troubleshooting Guide.

Table 1-2.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions