Dell PowerEdge 6850 User Manual
Page 10
8
Information Update
E0412
RPM FAN PS BLANK Power supply fan RPM is out
of acceptable range.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
E0412
RPM FAN n
FAN REDUNDANCY
LOST
Specified cooling fan is faulty,
improperly installed, or missing.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
E0780
PROC # CONFIG
ERR
The specified processor has a
configuration error.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide.
E0780
PROC # DISABLED
The specified processor is
disabled.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide.
E0780
PROC n PRESENCE
Microprocessor is not installed
in socket n.
Install a microprocessor in socket
n. See "Installing a Processor"
in your Installation
and Troubleshooting Guide.
E07F0
PROC n IERR
Faulty or improperly installed
microprocessor.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide.
Table 1-2.
LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions