ADJUSTMENTS - ILL. B


WATER FLOW RATE

The Dispense Valves are factory adjusted fo r a maximum Flow Rate of 1 to 1.3 oz./sec.
[Approximate settings: 0.85 to 1 oz./sec for SOUP; 1.3 oz./sec. for COFFEE and CAPPUCCINO]

Exceeding this Flow Rate will cause the Mixing Chamber to overflow.

Note: To access the Water Dispense Valves, open door and remove Hoppers.


TO ADJUST WATER FLOW RATE:

1. Open door and remove hoppers. Locate Dispense Valve behind hoppers, mounted on tank.

2. Locate adjustment screw on Dispense Valve.

3. Using Allen Key or flat screwdriver rotate, 1/4 turn at a time,

CLOCKWISE to decrease water flow, or

COUNTERCLOCKWISE

to increase water flow.

4. Check water flow output, after each 1/4 turn.


HOPPERS AND AUGERS

CD130 NYLON AUGER [22.5mm%%c X 17mmPT]

W/O-RING CD139


CD101 WIRE AUGER [22.5mm%%c X 17mmPT]

CAPPUCCINO/FAST FLOW & SOUP

CD149 WIRE AUGER {22.5mm%%c X 24.8mmPT]
HOT CHOCOLATE & THICK SOUP

CD74A WIRE AUGER {17mm%%c X 12mmPT]

DRY COFFEE/FAST FLOW

CD153 WIRE AUGER [17mm%%c X 9.15mmPT]

DRY COFFEE & INSTANT ESPRESSO



A. When using NYLON AUGERS:

Adjust Water Flow Rate so that the
water level reaches almost at the top

in the Mixing Chamber, as shown.

B. When using WIRE AUGERS:
Adjust Water Flow Rate so that the

water level reaches half way up

in the Mixing Chamber, as shown.




CD76A

AUGERS:

CD90A

PRODUCT
GUIDE
CD70A

AUGER GEAR

CD117 [w/NYLON AUGER CD130]
CD117 [w/WIRE AUGER CD101 & CD149]
CD97A [w/WIRE AUGER CD74A & CD153]

CORRECT WATER
LEVEL FOR MAX
FLOW RATE WHEN
USING WIRE AUGER

CORRECT WATER
LEVEL FOR MAX
FLOW RATE WHEN
USING NYLON

AUGER

RECTANGULAR RIB

DISPENSE CAP

CD61A

DISPENSE CAP

CD61A

CD115

SPLASH GUARD

MIXING CHAMBER CD145

FAST FLOW [COLD]

MIXING CHAMBER CD137

FAST FLOW [HOT]

MIXING CHAMBER CD62A

SOUP UNITS

TRIANGULAR

RIB

OR