Cecilware GB-IT User Manual
Page 17
17
RECOMMENDED PREVENTIVE MAINTENANCE
1. CHECK ALL DISPENSE VALVES FOR LIME BUILD-UP.
•Drain The Water Tank To Just Below The Level Of The Dispense Valves.
•Remove The Valves And Clean. ( You Can Take
These Valves Apart By Hand As Shown).
•Replace The Assembly As Needed (L467A).
•Replace The Valve Into The Tank And Refill tank.
2. CHECK ALL CHAMBER MOUNTS FOR SIGNS OF WEAR
A. Product running down th front of the unit.
B. Product built up on the back of Chamber Mount.
•Remove Chamber Mount.
•Clean And Re-Lubricate motor shaft using food grade lubricant only
•Replace with new Chamber Mount.
3. CLEAN OUT VENT MOTOR, TROUGH AND TUBING
•Remove Two Screws Holding Trough In Place.
•Clean, And Replace Trough.
•Remove Hose Assembly From The Motor.
•Clean Out And Replace.
WATER FLOW ADJUSTMENT