beautypg.com

Cecilware GB-IT User Manual

Page 2

background image

2

ELECTRICAL SPECIFICATIONS

Model No.

Volts

Phase

Hz

Watts

Number of

Heaters

Amps

Receptacle

Nema No.

Circuit

Breaker

ALL MODELS

120V

1

60

1.8KW

1

15

5-15R

15A

ALL MODELS

120/240V

1

60

3.0KW

1

15

L14-20R**

20A

ALL EXPORT MODELS

220V

1

60

3.0KW

1

15

††

20A

GB3M-5.5-IT, GB4M-5.5-IT 120/240V

1

60

6.0KW

2

25

L14-30R**

30A

120V, 1.8 KW, 15A, Nema 5-15R standard on all models; 3.0 KW and 6.0 KW, 120/240V units available
** 120/240V, 3 pole, 4 wire grounding type Twist-Plug Receptacle. For 240V units, Use L6-20R or L6-30R, 2 pole, 3 wire Twist-Plug Receptacle.
†† 220V Export Receptacle to be specified where order is placed.
See Electrical Data Label attached to the back of the unit for proper voltages, breaker sizes and electrical outlet requirements for each model number
listed. See wiring diagram in back of manual, for wiring instructions.

UNPACKING INSTRUCTIONS

Carefully unpack the GB Machine and inspect immediately for shipping damage. Your GB Machine was shipped in a carton designed to give it

maximum protection in normal handling. It was thoroughly inspected before leaving the factory. In case of damage, contact the shipper, not

Cecilware.

INSTALLATION INSTRUCTIONS

Water Inlet Connection:

This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction. In addition:

1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for

cleaning underneath.

2. An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.

The GB beverage dispenser is equipped with a ¼" Flare Water Inlet Fitting which is located on the left side in the back of the base.


HIGHLY RECOMMENDED:

A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/Phosphate Filter, to remove odors and inhibit lime
and scale build up in the machine. Note: In areas with extremely hard water, a water softener must be installed in order to prevent a

malfunctioning of the equipment and in order not to void the warranty.


After the machine has been unpacked and placed on a counter, pull out the stainless steel drip tray. It should contain the following:

A Set of 4 Adjustable Leveling Legs & Water Inlet Fitting.

MECHANICAL SPECIFICATIONS

MODEL:

WIDTH

in

DEPTH

in

HEIGHT

in

Lb (qty)

TANK

GAL.

BURST

CAPACITY

LIT DISPLAY AREA

(W x H) Sq. in.

SHIPPG

WEIGHT LB.

GB1M-IT

8.5

22

34

8 (1)

2.2

58

(7 x 13) 91

65

GB2M-5.5-IT

8.5

22

34

5.5 (2)

2.2

58

(7 x 13) 91

86

GB3M-5.5-IT

11

22

34

4 (3)

3.2

85

(9½ x 13) 123

100

GB3M-5.5-IT S/S

11

22

34

5.5 (3)

3.2

85

(9½ x 13) 123

100

GB3M-IT-10 LEFT [11.5”W]

11.5

22

34

10 (1) + 5.5 (2)

4.5 112 (12

3

/

8

x 13) 164

110

GB3M-IT-10 RIGHT [11.5”W]

11.5

22

34

10 (1) + 5.5 (2)

4.5 112 (12

3

/

8

x 13) 164

110

GB4M-IT 14.125

22

34

5.5

(4)

4.5 112 (12

3

/

8

x 13) 164

120

GB5M-IT 17.25

22

34

5.5

(5)

4.5 140 (12

3

/

8

x 13) 164

140