beautypg.com

Cecilware GB-IT User Manual

Page 10

background image

10

PROGRAM MODE

General Conventions (unless otherwise indicated)
1. To enter or exit Program Mode simultaneously depress both the Rinse key and the Stop key until the buzzer sounds (approximately 1.5

seconds).

2. Pressing the Stop key will cause the menu to scroll up and pressing the Rinse key will cause the menu to scroll down.

3. The blinking LED's) signify which Hopper or Serving Size the displayed parameter corresponds to.
4. Pressing the ▼or ▲ keys individually will decrease or increase the displayed parameter respectively.

5. Pressing the ▼and ▲ simultaneously will cause the parameter to revert to a default value.

Functions:

1.

All Dispense LED’s will be illuminated and the LCD/VFD screen will display the following:

DISPENSE TOTAL

SELECT A KEY

2. If

the

Stop key is pressed the LCD/VFD screen will display the following:

DISPENSE TOTAL

#######.# OZ.

3.

Pressing any of the Dispense keys will cause the Dispense LED of the corresponding key to
blink and the LCD/VFD screen will display the serving counter for the indicated Dispense

key as follows:

SERVING COUNTER

SELECT A KEY

4.

Pressing any of the Dispense keys will cause the Dispense LED of the corresponding key to
blink and the LCD/VFD screen will display the Serving Counter for the indicated Dispense

key as follows:

SERVING COUNTER

##### CUPS

5.
6.

If the Stop key is pressed the LCD/VFD screen will display the following:
If the▼or ▲ keys are pressed the Dispense Mode will toggle between “free flow” and

“portion control”.

DISPENSE

MODE FREE

FLOW

DISPENSE MODE

PORTION CONTROL

7. If

the

Stop key is pressed the LCD/VFD screen will display the following:

TEACH-ME SETUP

ARE YOU SURE ?

8. Pressing

the

▼and ▲ keys simultaneously will cause the menu to display the following:

TEACH-ME SETUP

SELECT A KEY

Teach Me Timer Setup
A. Place cup or decanter under the desired nozzle.
B. Press one of the illuminated Dispense keys corresponding to the selected nozzle to begin dispensing.
C. Release the Dispense key to stop dispensing.
D. Wait a short time to allow the foam to settle.
E. Jog the Dispense key as needed to top off cup or decanter.
F. If desired simultaneously press the ▼and ▲ keys to use the last Serving Size for all equal cup sizes.

Repeat steps A-F for each Dispense key as required.

9. If

the

Stop key is pressed the LCD/VFD screen will display the following:

SERVING SIZE

SELECT A KEY

10. Pressing any of the Dispense keys will cause the Dispense LED of the corresponding key to

blink and the LCD/VFD screen will display the Serving Size for the indicated Dispense key
as follows:

SERVING SIZE

##.# OZ.

11. Pressing

▼or ▲ key will decrease or increase the Serving Size respectively.

12. If

the

Stop key is pressed the LCD/VFD screen will display the following:

GRAM THROW

SELECT A KEY