Absolute Maximum Conditions

Parameter

Description

Condition

Min

Max

Unit

V

DD

Clock Buffer Supply Voltage

–0.5

4.6

V

V

DDC

Core Supply Voltage

–0.5

4.6

V

V

DDP

PLL Supply Voltage

–0.5

4.6

V

V

IN

Input Voltage (SCL and SDA)

Relative to V

SS

–0.5

4.6

V

Input Voltage (REFCLK/REFCLKB

)

Relative to V

SS

–0.5

V

DD

+ 1.0

V

Input Voltage

Relative to V

SS

–0.5

V

DD

+ 0.5

V

T

S

Temperature, Storage

Non-functional

–65

150

°C

T

A

Temperature, Operating Ambient

Functional

0

70

°C

T

J

Temperature, Junction

Functional

150

°C

Ø

JA

Junction to Ambient thermal resis-
tance

Zero air flow

100

°C/W

ESD

HBM

ESD Protection (Human Body Model) MIL-STD-883, Method 3015

2000

V

REFCLKB

REFCLK

Input

XDR Clock Generator

Input

XDR Clock Generator

REFCLK

Supply Voltage

V

TH

Differential Input

Single-ended Input