4.2.3. Read device status „F“ (46h)
This command provides the device statii Stat1 and Stat2 together with error flags Err1, Err2. In case of error
check command “C” will come with an “e” in reply.
Example:
SOH Adr Cmd EOT CRC
Transmission
01h 20h 46h 04h 00h
SOH Adr Cmd Stat1 Stat2 Err1 Err2 EOT CRC
Response
01h 20h 46h 80h 80h 80h 80h
04h
4Bh
Stat1: 1 0 0 0 0 0 0 X
┬ ─────┬───── ┬
│ │ └──
Motor on standby for transmission
│ │
0 = No motor start signal. SPA does not transmit any IR data
│ │
1 = Motor start signal.
│ │ Interactive mode (motor start by broadcast command):
│ │ SPA is enabled for alignment by power tool, however so far there
│ │ has not been any IR data transmission. LED is flashing slowly.
│ │ Motor start is enabled using the key.
│ │ Direct mode (motor start signal via device address):
│ │ SPA is enabled for alignment by power tool, IR data are being
│ │ transmitted. LED is flashing.
│ └───────── reserved
└──────────────── ever 1
Stat2: 1 0 0 0 0 0 0 X
┬ ─────┬───── ┬
│ │ └── 1 = Motor is running (Moving Bit). The bit is set during motor start
│ │ enable. LED is flashing rapidly.
│ └───────── reserved
└──────────────── ever 1
Err1: 1 0 0 0 0 0 X X
┬ ──┬── ┬ ┬ ┬ ┬
│ │ │ │ │ └── 1 = Err 8 - target > MAX limit position (motor does not start)
│ │ │ │ └──── 1 = Err 9 - target < MIN limit position (motor does not start)
│ │ │ └────── reserved
│ │ └──────── reserved
│ └──────────── reserved
└──────────────── ever 1
Err2: 1 0 0 X 0 0 X X
┬ ┬ ┬ ┬ ┬ ┬ ┬ ┬
│ │ │ │ │ │ │ └── 1 = Err 1 - hurt MAX limit position
│ │ │ │ │ │ └──── 1 = Err 2 - hurt MIN limit position
│ │ │ │ │ └────── reserved
│ │ │ │ └──────── reserved
│ │ │ └────────── 1 = Err 5 – target not achieved
│ │ └──────────── reserved
│ └────────────── reserved
└──────────────── ever 1