Manual_GNAMG_Profibus_EN.doc 9/19

Baumer IVO GmbH & Co. KG

04.05.11

Villingen-Schwenningen,

Germany

Parameter values of parameterization function (Set_Prm)

Parameter

Data

type

Octe

t Nr.

Value range

Default parameter
in GSD file

Station status

Octet

string

1

• Sync and freeze

mode supported

• Supported

baud

rates

Response monitoring
time

Octet

string

2 to 3

Profibus-specific
data

Minimum Station Delay
Responder

Octet

string

4

Depending on Baud
rate

Ident No.

Octet

string

5 to 6

059B

Group Ident No.

Octet

string

7

00

Operating parameter

Octet

string

8

Profibus-specific
data

Parameters of the
inclination sensor

Octet

string

9

• Bit 0 = 0/1 inversion X-axis
• Bit 1 = 0/1 inversion Y-axis
• Bit 2 = 0/1 scaling X-axis
• Bit 3 scaling Y-axis
• Bit 4 = 0/1 standard

diagnosis/ extended
diagnosis

• less inversion

• less inversion

• less scaling

• less scaling
• extended

diagnosis

Resolution

Octet

string

10

0x00 to 0x03

0x00 = 0.001° Resolution
0x01 = 0.01° Resolution
0x10 = 0.1° Resolution
0x11 = 1.0° Resolution


Default = 0x10 =
0.1°