Baumer GNAMG User Manual
Page 11
Manual_GNAMG_Profibus_EN.doc 11/19
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
6.3. Significance of diagnostic data Slave_Diag
Diagnostic data
Octet
Nr.
Significance
Station status 1
1
1 Status
of
• Parameterization
• Configuration
• Diagnostic data (Diag.ext. Bit and Diag.stat. bit in case
of alarm and warning signals)
Stations tatus 2
2
2 Status
of
• Response
monitoring
• Freeze or sync mode
Stations tatus 3
3
3
Not supported
Diag_Master
4
Address of the master having parameterized the slave first
Ident_no.
5 bis 6
Recognition of the device
• Unique for each device type
• Defined and reserved by the PNO
Extended
Diagnosis header
7
Length of the extended diagnosis including diagnosis
header byte in case of extended diagnosis
Operating parameter
8
According to parameterization
Alarms 9
At
present
no alarms are supported.
Supported Alarms
10
Defining the supported alarms
Warnings
11
At present no warnings are supported.
Supported Warnings
12
Defining the supported warnings
Firmware Version
13,14
7-8
Firmware version number
MAX limit positive
15-18
Maximum positive limit range ( 33 / 330 / 3300 / 33000)
MAX limit negative
19-22
Maximum negative limit range (-33 / -33 / -3300 / -33000)
Calibration Value X-
high
23,24
10-13
Calibration value X-axis (max)
Calibration Value X-
low
25,26
14-17
Calibration value X-axis (min)
Calibration Value Y-
high
27,28
18-21
Calibration value Y-axis (max)
Calibration Value Y-
low
29,30
22-25
Calibration value Y-axis (min)
Serial number
31-34
26-29
Serial number of inclination sensor
Offset X
35-38
30-33
Programmed offset X-axis
Offset Y
39-42
34-37
Programmed offset Y-axis
Preset X
43-46
38-41
Programmed preset X-axis
Preset Y
47-50
42-45
Programmed preset Y-axis
Resolution
51-52
46,47
Presently selected resolution