6. Parameterization and configuration

6.1. Parameterization

Parameterization refers to transfer of information required by the slave for process data exchange. The
information comprises Profibus-specific data (octet 1 to 6) as well as user-specific information. User-
specific information can be entered via an input window during the project processing phase.
The data received from master are compared by the slave with the data it has stored. However, the slave
will only inform the master of the result in the diagnosis request after configuration.

Parameter description for the parameterization function (Set_Prm)

Parameter

Octet Nr.

Significance

Station status

1

Definition of profibus-specific data
• Sync mode/freeze mode active
• Response monitoring active
• Master

assigned

Response monitoring time

2 to 3

Recognition of master failure, master must respond
within this time

Min. Station Delay
Responder (tsdr)

4

Minimum time the slave has to wait until it is allowed
to respond to a master’s request

Ident_No.

5 to 6

Device identifier, unique for each device type,
defined and reserved by the PNO

Group_Ident_No.

7

Profibus-specific data

Operating parameter

8

Profibus-specific data

Parameters of the
inclination sensor

9

Definition of application-specific data
• Inversion of the inclination angles of the axis
• Scaling

function

• Standard diagnosis/ extended diagnosis
• Resolution

Resolution

10

Parameter location for four optional resolutions