Object 0x1011 RESTORE Application Parameter
Object 0x1011 restores ROM default in device-specific objects (0x6000..0x6FFF) both in RAM and EEPROM. To
prevent any inadvertent restore, the signature „load“ must be written in object 0x1011 Subindex 0.
Signature
MSB
LSB
ISO 8859 character
hex
Object 0x1018 Identity Object
SubIndex 0
Data type
Unsigned 8
Access ReadOnly
Default 4
EEPROM No
Significance Maximum supported subindex
Values
4 = Maximum supported subIndex
SubIndex 1
Data type
Unsigned 32
Access ReadOnly
Default Ech
EEPROM No
Significance
VendorID for Baumer IVO GmbH & Co. assigned by CiA
Values
0xEC (in the Internet under www.can-cia.de)
SubIndex 2
Data type
Unsigned 32
Access ReadOnly
Default 0x0A
Æ
GXMMW_H ; 0x0B Æ GXAMW_H
0x0C Æ GCMMW_H ; 0x0D Æ GCAMW_H
0x0E Æ GBMMW_H, GDMMW_H ; 0x0F Æ GBAMW_H, GDAMW_H
EEPROM No
Significance Product
Code
Values
SubIndex 3
Data type
Unsigned 32
Access ReadOnly
Default
EEPROM No
Significance
Revision no.
Values
SubIndex 4
Data type
Unsigned 32
Access ReadOnly
Default
EEPROM No
Significance
Serial no.
Values
d a o l
0x64 0x61 0x6F 0x6C