Cullsorb filter specifications – Culligan HD-726 User Manual
Page 5
H
I
-F
LO
®
C
ULLSORB
®
A
UTOMATIC
F
ILTERS
FOR
I
RON
AND
M
ANGANESE
R
EDUCTION
S
PECIFICATIONS
AND
O
PERATING
D
ATA
Hi-Flo 55
Hi-Flo 50
MODEL NUMBER
HG-202 HG-242 HG-302 HG-362 HG-423
HG-4825 HG-5425 HG-6025 HG-723 HG-844
Service Flow @
gpm
10
15
25
35
50
65
80
100
140
190
Pressure Drop
@ psi
@ 3
@ 3
@ 4
@ 4
@ 4
@ 4
@ 6
@ 4
@ 5
@ 6
L/min
38
57
97
132
190
250
300
380
530
720
@ kPa
@ 21
@ 21
@ 28
@ 28
@ 20
@ 28
@ 41
@ 28
@ 34
@ 41
Backwash Flow
gpm
30
45
70
100
135
160
210
240
350
480
L/min
110
170
270
380
510
610
800
910
1,330
1,820
Tank Size
Diameter
in
20
24
30
36
42
48
54
60
72
84
mm
510
610
760
910
1,070
1,220
1,370
1,520
1,830
2,130
Sideshell
in
48
48
48
54
54
60
60
60
60
60
mm
1,220
1,220
1,220
1,370
1,370
1,520
1,520
1,520
1,520
1,520
Pipe Size
Inlet/Outlet
in
2
2
2
2
3
2.5
2.5
2.5
3
4
Media Volume
ft
3
5
8
12
19
25
34
43
53
76
104
m
3
0.156
0.212
0.340
0.538
0.708
0.962
1.22
1.50
2.15
2.94
Ship Weight, Approx.
lb
850
1,150
1,790
2,680
3,720
7,200
9,100
11,600 17,500 27,000
kg
385
522
812
1,220
1,690
3,300
4,100
5,300
7,900
12,000
NOTES:
1 Service flow rates are based on 5 gpm/ft
2
(19 L/m
2
/min). Actual flow rate may vary depending upon the application and the raw water.
2 Backwash flow rates are based on 12-14 gpm/ft
2
(45-53 L/m
2
/min) using 50° F (10° C) water. A different backwash rate may be required depending upon
water temperature or other water conditions.
3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently
operated Culligan dealerships.
Commercial Systems
©2000 Culligan
1-800-CULLIGAN
www.culligan.com
Printed in USA Rev. 4/00
DCO 992587
SL-0071
Moore Part No. 46925